FTD CLUSTER BUG
FTD Version 7.2.5 when trying to create a cluster
FTD CLI
sec-dcfw-01#
Detected Cluster Master.
Beginning configuration replication from Master.
..
Cryptochecksum (changed): 2f2f9cae ea5dbc33 a1eb4bda 3379b6fb
End configuration replication from Master.
Unit is kicked out from cluster because of interface health check failure.
Cluster disable is performing cleanup..done.
All data interfaces have been shutdown due to clustering being disabled. To recover either enable clustering or remove cluster group configuration.
Searching the error i found the bug
https://bst.cisco.com/quickview/bug/CSCus54932
Upgrade to 7.4.2 (currently recommended) the cluster builded as expected.